⚡ LARGE AC MOTOR • ENGINEERING CASE STUDY

Overhaul CROMPTON Motor 500 kW • Housing Repair • Electrical Repair • Final Test

Case Study งาน Overhaul มอเตอร์ไฟฟ้าอุตสาหกรรมขนาดใหญ่ 500 kW / 670 HP ครอบคลุม Stator Cleaning & Insulation Treatment, Power Lead Repair, Bearing Housing Rebush, Bearing Renewal, Shaft & Hardware Repair พร้อม Insulation Test, Surge Comparison, No-Load Run Test, Shaft Run-out, Vibration และ Temperature Measurement ก่อนส่งมอบ

⚡ CROMPTON • 500 kW / 670 HP 🔄 3,579 RPM • 2-Pole 🔌 400 V / 825 A ⚖️ MOTOR WEIGHT • 2,030 kg 🏭 LARGE INDUSTRIAL MOTOR
500 kW Rated Motor Power • 670 HP
2,030 kg Motor Weight
0.74–0.86 Final DE Vibration • mm/s
0.005 mm Final Recorded Shaft Run-out

Inspection, Overhaul & Mechanical Repair Scope

LARGE MOTOR • 500 kW
Manufacturer:
CROMPTON
Type:
Y2-355LX-2
Rated Power:
500 kW (670 HP)
Recorded Speed:
3,579 RPM • 2-Pole
Voltage / Current:
400 V / 825 A
Motor Weight:
2,030 kg
Insulation Class:
Class F
Protection:
IP55
DE Bearing:
SKF 6219/C3
NDE Bearing:
SKF 6219/C3

📋 Incoming Condition

  • ตรวจพบ Power Lead / Motor Lead ชำรุด โดยมีหัวสายขาด ฉนวนบริเวณปลายสายเสียหายจากความร้อน และ Cable Lug มีสภาพเสื่อม
  • Bearing Housing ด้าน DE และ NDE มีการสึกหรอและหลวม พร้อมร่องรอยการเสียดสีกับ Bearing โดยค่าที่บันทึกก่อนซ่อมประมาณ DE Ø170.05 mm / NDE Ø170.04 mm
  • ตรวจพบร่องรอย Electrical Arc Mark บริเวณปลายเพลาฝั่งหน้า จำนวนประมาณ 4 ตำแหน่ง ตาม Inspection Record ของงาน
  • External Retaining Ring มีการบิดงอเสียรูป และ Hardware / Fastener บางรายการมีสภาพเกลียวชำรุด
  • Incoming Insulation Resistance ที่บันทึกได้ประมาณ 200 MΩ @ 500 Vdc ซึ่งใช้เป็นข้อมูลประกอบการประเมิน สภาพระบบฉนวนร่วมกับ Inspection
  • ไม่สามารถบันทึก Incoming No-Load Run Data ได้อย่างสมบูรณ์จากสภาพ Power Lead ที่ชำรุดก่อนการซ่อม

🔧 Scope of Repair

Stator Cleaning

ทำความสะอาด Stator Winding และตรวจสภาพระบบฉนวน ตาม Scope ของ Motor Overhaul

Power Lead Repair

จัดทำ / ซ่อม Power Lead ใหม่ จำนวน 2 เส้น พร้อม Cable Lug ตามรายการงานซ่อม

Varnish Treatment

ทำ Insulation Treatment, Varnish Process และ Drying ตามสภาพขดลวดและ Repair Procedure ของ Job

DE Housing Rebush

ซ่อม Bearing Housing DE ด้วย Sleeving / Rebush และ Finish Machining ไปยังค่าที่บันทึกประมาณ Ø170.01 mm

NDE Housing Rebush

ซ่อม Bearing Housing NDE และ Finish Machining ไปยังค่าที่บันทึกประมาณ Ø170.01 mm

Bearing Renewal

เปลี่ยน Bearing SKF 6219/C3 ทั้งด้าน DE และ NDE ตามรายการอะไหล่ของเครื่อง

Shaft Arc-Mark Repair

ซ่อมและตกแต่งบริเวณ Electrical Arc Mark ที่ปลายเพลาฝั่งหน้า ตาม Inspection Record

Hardware Renewal

เปลี่ยน External Retaining Ring, Cable Lug CL 70-12 และ Bolt & Nut ตามรายการซ่อม

Electrical Testing

ตรวจ Insulation Resistance และ Surge Comparison ตาม Test Procedure ของ Job นี้

No-Load Final Run

เดินเครื่อง No-Load Test ประมาณ 30 นาที พร้อมบันทึก Current, Vibration, Shaft Run-out และ Temperature

INSPECTION & FINAL RECORDED DATA

ผลการตรวจสอบและ Final Test หลัง Overhaul

แสดงค่าที่บันทึกจากงานจริงของ Motor เครื่องนี้ โดยแยก Measured Result, Repair Dimension และ Test Condition ออกจาก Acceptance Criteria เพื่อไม่ใช้ Threshold เดียวกับมอเตอร์ทุกประเภท

>500 MΩ FINAL RECORDED IR @ 500 Vdc
273 A FINAL RECORDED NO-LOAD CURRENT
0.74–0.86 FINAL DE VIBRATION • mm/s
0.005 mm FINAL SHAFT RUN-OUT
Parameter Incoming Final Recorded Engineering Record
Insulation Resistance @ 500 Vdc 200 MΩ >500 MΩ Recorded insulation values; evaluation should consider winding condition, temperature, machine data and applicable test criteria
Bearing Housing DE / NDE Ø170.05 / Ø170.04 mm Ø170.01 / Ø170.01 mm Final repair dimensions recorded after Sleeving / Rebush and Machining
No-Load Current Incoming run not available due to damaged lead condition 273 A Recorded during available Final No-Load Test; not evaluated only against rated current 825 A
Final Vibration DE Noise / rubbing condition recorded before repair; no numeric incoming value shown V: 0.86 mm/s
H: 0.74 mm/s
Final measured values under the available Run Test condition
Final Vibration NDE Noise / rubbing condition recorded before repair; no numeric incoming value shown V: 0.81 mm/s
H: 0.79 mm/s
Final measured values under the available Run Test condition
Shaft Run-out — 0.005 mm Final mechanical measurement recorded for this Job
Bearing / Frame Temperature — Bearing: 61 °C
Frame: 44 °C
Recorded temperatures; interpretation depends on ambient temperature, run duration, load and measurement position
⚡ SURGE COMPARISON Test setting recorded at 1,100 V for this Job
🔄 NO-LOAD RUN Final Run Test approximately 30 minutes
📐 SHAFT RUN-OUT Final recorded value: 0.005 mm
📊 FINAL VIBRATION DE / NDE measurement recorded after assembly
⚡
ELECTRICAL TEST NOTE — IR, SURGE & NO-LOAD CURRENT

ค่า Insulation Resistance 200 MΩ ก่อน Overhaul และมากกว่า 500 MΩ หลัง Overhaul เป็นค่าที่บันทึกสำหรับเครื่องนี้ ไม่ควรตีความว่า 200 MΩ เป็น Fail จาก Threshold ตัวเลขเดียว การประเมินควรพิจารณา Rated Voltage, Winding Condition, Temperature, Test Method, OEM Requirement และ Repair Scope ร่วมกัน ส่วน Final No-Load Current 273 A เป็นค่าที่บันทึกภายใต้ Test Condition ของงาน และไม่ควรสรุป Pass เพียงเพราะ ต่ำกว่า Rated Current 825 A

⚙️
MECHANICAL NOTE — 6219/C3 & HOUSING REPAIR

Motor เครื่องนี้ระบุ Bearing SKF 6219/C3 ทั้งด้าน DE และ NDE และข้อมูล Bearing Housing ที่บันทึกอยู่บริเวณประมาณ Ø170 mm สอดคล้องกับตำแหน่ง Outer-Race Housing ของชุด Bearing ที่ใช้ ค่า Ø170.01 mm ที่แสดง จึงนำเสนอเป็น Final Repair Dimension ของ Job นี้โดยเฉพาะ ไม่ใช่ Universal Fit สำหรับมอเตอร์หรือ Bearing ทุกเครื่อง

📐
ENGINEERING NOTE — VIBRATION, RUN-OUT & TEMPERATURE

Incoming Record ของเคสนี้ ไม่มีตัวเลข Vibration ก่อนซ่อมที่ชัดเจน จึงไม่ควรสร้างเปอร์เซ็นต์การลด Vibration หรือ Before / After Ratio ขึ้นมาเอง ค่าที่ควรนำเสนอคือ Final Recorded Data จริง ได้แก่ DE 0.86 / 0.74 mm/s, NDE 0.81 / 0.79 mm/s, Shaft Run-out 0.005 mm และ Bearing / Frame Temperature 61 °C / 44 °C การตีความค่าดังกล่าวควรพิจารณา Test Speed, Support Condition, Measurement Position, Ambient Temperature, Run Duration, Load Condition, OEM Data และข้อกำหนดของงาน

⚡ ELECTRICAL + MECHANICAL งานเดียวครอบคลุม Stator, Power Lead, Housing, Bearings, Shaft และ Hardware ตาม Scope ของ Job
📊 RECORDED TEST DATA แสดง IR, Housing Dimension, Current, Vibration, Run-out และ Temperature จากข้อมูลของงานจริง
📋 ISO 9001:2015 QMS กระบวนการตรวจสอบ, ซ่อม, ทดสอบ และบันทึกข้อมูล ดำเนินภายใต้ระบบบริหารคุณภาพ ISO 9001:2015

มอเตอร์ขนาดใหญ่มีปัญหา สายไฟเสีย Housing หลวม Bearing ดัง หรือ Run Test ผิดปกติ?

ส่งรูป Nameplate, Motor, Terminal / Power Lead, Bearing, Shaft / Housing และข้อมูล Electrical / Vibration ที่มี ให้ทีม Futuretech Electric เพื่อช่วยประเมินแนวทาง Inspection, Overhaul, Mechanical Repair, Bearing Renewal และ Final Testing เบื้องต้น