Overhaul NINEC Motor 450 kW • 2,990 RPM • Housing Repair & Rotor Balancing

Case Study งาน Overhaul มอเตอร์ไฟฟ้าอุตสาหกรรม ขนาด 450 kW ความเร็ว 2,990 RPM ครอบคลุม Stator Cleaning & Insulation Treatment, Bearing Housing Rebush, Bearing Renewal, Rotor Inspection & Dynamic Balancing พร้อม Electrical Test, No-Load Run Test และ Vibration Measurement หลังประกอบ

📋 JOB 68091455 ⚡ NINEC • 450 kW 🔄 2,990 RPM • 2-POLE 🔌 380 / 690 V • 779 / 432 A 🏭 LARGE INDUSTRIAL MOTOR
450 kW Rated Motor Power
2,990 RPM High-Speed • 2-Pole Motor
3.95 → 0.36 Max Recorded Vibration • mm/s
≈91% Maximum Recorded Vibration Reduction

Inspection, Overhaul & Mechanical Repair Scope

Job No. 68091455
Manufacturer:
NINEC
Job No.:
68091455
Type:
COM.6
Serial No.:
94110301HC03
Rated Power:
450 kW
Rated Speed:
2,990 RPM • 2-Pole
Voltage:
380 / 690 V
Rated Current:
779 / 432 A
Frequency:
50 Hz
DE Bearing:
6317/C4
NDE Bearing:
6317/C4
Repair Type:
Overhaul + Housing Repair

📋 Incoming Condition

  • Bearing Housing ด้าน DE และ NDE มีการสึกหรอและหลวม โดยค่าที่บันทึกก่อนซ่อมประมาณ DE Ø180.05 mm / NDE Ø180.04 mm
  • ค่า Insulation Resistance ที่บันทึกก่อน Overhaul ประมาณ 200 MΩ @ 500 Vdc จึงนำข้อมูลดังกล่าวมาใช้ร่วมกับ Inspection Condition ในการประเมินงาน Stator
  • Run Test ก่อนซ่อม บันทึกค่าความสั่นสะเทือน ด้าน DE สูงสุดประมาณ 3.81 mm/s
  • ด้าน NDE บันทึกค่าความสั่นสะเทือน สูงสุดประมาณ 3.95 mm/s ภายใต้สภาวะการทดสอบก่อนงานซ่อม
  • Rotor และระบบ Bearing อยู่ใน Scope การตรวจสอบสภาพ และ Dynamic Balancing ก่อน Final Assembly

🔧 Scope of Repair

Stator Cleaning

ทำความสะอาด Stator Winding และตรวจสภาพระบบฉนวน ตาม Scope ของ Motor Overhaul

Insulation Treatment

ดำเนินการ Varnish / Drying Treatment ตามสภาพขดลวด และ Repair Procedure ของ Job นี้

DE Housing Rebush

คว้านและตีปลอกซ่อม Bearing Housing DE พร้อม Finish Machining ไปยังค่าที่บันทึกประมาณ Ø180.01 mm

NDE Housing Rebush

ซ่อม Bearing Housing NDE ด้วย Sleeving / Rebush และ Finish Machining ไปยังค่าที่บันทึกประมาณ Ø180.01 mm

Bearing Renewal

เปลี่ยน Bearing ใหม่ DE / NDE รหัส 6317/C4 ตามรายการอะไหล่ของเครื่อง

Rotor Inspection

ตรวจ Shaft, Rotor Condition และจุดประกอบที่เกี่ยวข้อง ก่อนการทำ Balancing

Rotor Dynamic Balancing

ตรวจและปรับสมดุล Rotor ตาม Balance Criteria ที่กำหนดสำหรับ Rotor, Speed และ Scope ของ Job นี้

Electrical Inspection

ตรวจ Insulation Resistance และ Surge Comparison ตาม Test Procedure ของงาน

No-Load Run Test

เดินเครื่องทดสอบ ประมาณ 30 นาที พร้อมบันทึก Phase Current และ Vibration

Final Mechanical Inspection

ตรวจการประกอบ, Bearing Condition, Fastener และ Mechanical Condition ก่อนส่งมอบ

INCOMING & FINAL RECORDED DATA

ผลตรวจสอบก่อนซ่อม และ Final Test หลัง Overhaul

แสดงข้อมูล Inspection, Repair Dimension และ Final Test ที่บันทึกสำหรับ Job 68091455 โดยแยกค่าที่วัดได้ออกจาก Acceptance Criteria ของเครื่องจักร

200 → 500 MΩ RECORDED IR @ 500 Vdc
3.81 → 0.36 DE MAX VIBRATION • mm/s
3.95 → 0.36 NDE MAX VIBRATION • mm/s
246 / 247 / 249 A FINAL NO-LOAD PHASE CURRENT
Parameter Incoming Final Recorded Engineering Record
Insulation Resistance @ 500 Vdc 200 MΩ 500 MΩ Recorded IR values; evaluation should consider winding condition, temperature, machine data and applicable job criteria
Bearing Housing DE / NDE Ø180.05 / Ø180.04 mm Ø180.01 / Ø180.01 mm Final repair dimensions recorded after Sleeving / Machining
No-Load Current @ 380 V — R: 246 A
S: 247 A
T: 249 A
Recorded phase current during available No-Load Test condition; evaluate phase balance and motor design together
Vibration DE V: 3.76 mm/s
H: 3.81 mm/s
V: 0.32 mm/s
H: 0.36 mm/s
Recorded before / after repair under available Run Test condition
Vibration NDE V: 3.95 mm/s
H: 3.44 mm/s
V: 0.30 mm/s
H: 0.36 mm/s
Recorded before / after repair under available Run Test condition
Rotor Dynamic Balancing Correction required G2.5
per job balancing record
Balance grade shown as recorded for this Rotor / Job; not a universal requirement for every motor
⚡ INSULATION TEST Final recorded IR: 500 MΩ @ 500 Vdc
🔄 NO-LOAD RUN Run duration: approximately 30 minutes
📊 PHASE CURRENT 246 / 247 / 249 A recorded during Final No-Load Test
⚖️ ROTOR BALANCING G2.5 shown as Job-Specific balancing record
⚡
ELECTRICAL TEST NOTE — IR & NO-LOAD CURRENT

ค่า Insulation Resistance 200 MΩ ก่อน Overhaul และ 500 MΩ หลัง Overhaul เป็นค่าที่บันทึกจาก Job นี้ จึงไม่ควรตีความว่า 200 MΩ เป็น Fail จาก Threshold ตัวเลขเดียว โดยควรพิจารณาร่วมกับ Winding Condition, Temperature, Rated Voltage, Test Method, OEM Requirement และ Repair Scope ส่วน No-Load Current 246 / 247 / 249 A เป็นค่ากระแสแต่ละเฟส ภายใต้ Test Condition ของงานนี้ ไม่ควรสรุป Pass เพียงเพราะ ต่ำกว่า Rated Current 779 A

📐
ENGINEERING NOTE — VIBRATION & BALANCING

ค่า Vibration หลังงานซ่อม ลดลงอย่างชัดเจนจากค่าที่บันทึก ใน Incoming Run Test โดยค่าที่สูงที่สุดลดจาก 3.95 mm/s เหลือประมาณ 0.36 mm/s อย่างไรก็ตาม ค่า Overall Vibration และ Balance Quality Grade เป็นคนละพารามิเตอร์ ค่า G2.5 ที่แสดง เป็นเกณฑ์ที่บันทึกสำหรับ Rotor / Job นี้ การกำหนด Acceptance Criteria ควรพิจารณา Machine Configuration, Rotor Speed, Bearing Arrangement, Support Condition, Measurement Position, OEM Data และ Customer Requirement

⚙️ LARGE MOTOR OVERHAUL ครอบคลุม Stator, Housing, Bearings, Rotor และ Mechanical Inspection ตาม Scope ของ Job
📊 RECORDED TEST DATA แสดง Incoming / Final Data จริง ทั้ง IR, Housing Dimension, Current และ Vibration
📋 ISO 9001:2015 QMS กระบวนการตรวจสอบ, ซ่อม, ทดสอบ และบันทึกข้อมูล ดำเนินภายใต้ระบบบริหารคุณภาพ ISO 9001:2015

มอเตอร์ขนาดใหญ่มีปัญหา Housing หลวม, Bearing เสื่อม หรือ Vibration สูง?

ส่งรูป Nameplate, Motor, Bearing, Shaft / Housing, Rotor และข้อมูล Vibration หรือ Electrical Test ที่มี ให้ทีม Futuretech Electric เพื่อช่วยประเมินแนวทาง Overhaul, Mechanical Repair, Bearing Renewal, Dynamic Balancing และ Final Testing เบื้องต้น